Pig manure equipment needs regular maintenance service, we provide detailed maintenance you need note: keep the workplace clean, every time after using the organic fertilizer equipment should be thoroughly remove granulation leaves and granulation sand pot inside and outside of residual glue, to ensure that the organic fertilizer equipment exposed processing surface is wiped clean and coated with anti-rust paint, set on the corresponding shield, prevent secondary invasion of dust.
Organic fertilizer equipment regardless of external refueling hole, gear, worm gear can be used for organic fertilizer equipment special butter lubrication. The upper gear and the lower gear should be buttered once a season, the moving gear box cover and the transmission gear cover can be opened respectively when refueling. Oil should be dripped frequently between the sliding surfaces of the supporting gear box and bracket hinge. Worm gear box and bearing have been used enough transmission butter when leaving factory, but after each year of use should be thoroughly cleaned the transmission machine, replace all the protection lubricant.
Always pay attention to the operation of the machine, there should be no serious abnormal noise, there should be no metal friction sound, such as abnormal, should immediately stop using, check, eliminate all the faults, then can be reused. You cannot start the machine if you cannot check the problems. If there is metal friction, check the gap between the equipment pelleting pot and the pelleting leaves.
Always check the standard clearance between the granulation pot and the granulation leaves. Every time the equipment is checked, the working clearance should be remeasured and adjusted for many times. Only after it meets the standard the equipment can be used continuously. Check organic fertilizer equipment electrical insulation condition (temperature insulation resistance in 22 + 6 ℃, relative humidity, 52-72% ≯ 13 Ω when cold feeling). If press the program controller organic fertilizer machine can’t work, check the power supply voltage, the power supply socket, connect the connector, and check the controller internal fault, make sure all is normal. Once the machine is found abnormal or malfunction, you should inform the professional maintenance personnel immediately, or return to the original factory for repair.
Post time: Sep-21-2020